SIM-01 Technical Specifications
OUTPUTS:
 |
ROTOR, 27 volt
peak to peak (p-p) square wave representative of either a magnetic or
optical probe output signal from a turbine generator rotor. ROTOR square wave frequency is front panel thumbwheel selectable over
a 240Hz to 6000Hz range. |
 |
REV
is a ± 13.5 volt zero to peak pulse. REV
pulse frequency is thumbwheel selectable over a 1 to 60 Hz range
. |
 |
REF–
60Hz is a fixed 27 volt p-p square wave phase locked to the input ac
nominal 60Hz power frequency.= |
 |
Fixed
Power Angles of 0º, ±15º, ±30º, ±60º and 90º are
selectable via pushbuttons from the front panel. |
 |
Continuously
Variable Power Angle output is provided via lockable coarse
and fine multi-turn precision
potentiometers. |
Power Required:
 |
120vac, 60 Hz, 15 volt-amps.
|
|