OP-01 Technical Specifications
Power Requirements:
±15 vdc required, 20 milliamperes from the positive supply and 90 milliamperes from the negative supply. Power may be supplied by end user or EUMAC model OP-PS power supply.
Usable Distance From Target:
0.5” (1.27cm) to 3.0” (7.62cm)
Temperature Range:
0º to 50º Centigrade
Usable Frequency Range:
0 to 6000Hz (i.e. output good down to standstill)