Technical
Specifications (Electrical)
 |
Input
Voltage Range
 |
High
input jacks - 5.0 volts to 1000 volts zero to peak (0-pk) |
 |
Switch
selectable range of 5, 10, 20, 50, 100, 200, 500, 1000 volts maximum |
 |
Low
input jacks - .05 volts to 10 volts zero to peak |
 |
Switch
selectable range of .05, 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 volts
maximum |
 |
Both
ranges fused for protection of equipment and personnel |
|
 |
Input
Impedance
 |
High
Range - 2.0 Megohms |
 |
Low
Range - 20 Kohms |
|
 |
Input
To Output Leakage Impedance
 |
Unmeasurable
(infinite ohms) |
|
 |
Output
Impedance
 |
75
ohms |
|
 |
Output
Level
 |
10
volts into 2000 ohms, 5 ma max current |
|
 |
Frequency
Response
 | DC
coupled, 0 to 91 KHz (-3dB
point) |
 |
AC
coupled, 0.2 to 91 KHz (-3dB points) |
|
 |
Power
Requirements
 |
two
9vdc alkaline batteries (standard configuration) |
 |
two
6 "AA" cell battery packs for extended operation (optional) |
 |
two
AC transformer modules for continuous operation without batteries
(optional) |
 |
power
consumption minimized by ultra efficient power supply design including
"POWER" LEDs that
flash on momentarily to indicate battery level is acceptable. LEDs come on continuously when cells reach half voltage. |
|

Technical
Specifications (Mechanical)
 |
Input
Connectors -
Fully Sheathed Banana Jack With No Exposed Metal Parts.
Connectors Mate With Standard Fluke & Pomona Test Leads. |
 |
Output
Connector -
One Pomona Type 3778 BNC Connector. |
 |
Switches
-
"Power", "Coupling" & "Range" Switches All
Are Insulated And Have No Exposed Metal That A User May Contact
|
 |
Size
-
2 inches by 8 inches by 7.25 inches (HWD) English Units OR 5.08 cm by 20.32
cm by 18.42 cm Metric Units
|
Weight:
 | 1